Informix Guide
SQLAPI++ allows to seamlessly work with a variety of SQL database servers. It provides unified API to access any database, keeping your code portable. But each server has some specific features which a developer has to know in order to leverage server's unique features and avoid potential errors.
For complete information on using SQLAPI++ check out Getting Started and Documentation. This guide covers specific information related to working with Informix server using SQLAPI++ library in the following areas:
- Connecting to a database
- Transaction isolation levels
- Working with Long or Lob (CLob, BLob) data
- Returning output parameters
- Cancelling queries
- Connection, command, parameter and field options
- Using native API
- Getting native connection related handles
- Getting native command related handles
- Error handling
Connecting to a database
To connect to a database you need to initialize a connection object. A connection object is represented by SAConnection class.
Minimum Version
After the connection is created you need to call SAConnection::Connect method to establish connection with Informix server:
void Connect(
const SAString &sDBString,
const SAString &sUserID,
const SAString &sPassword,
SAClient_t eSAClient = SA_Client_NotSpecified);
Parameters
sDBString
Any valid Informix connection string
sUserID
A string containing a user name to use when establishing the connection.
sPassword
A string containing a password to use when establishing the connection.
eSAClient
SA_Informix_Client
– Informix clientSA_Client_NotSpecified
– used by default ifeSAClient
parameter is omitted. You can use this default value only if you have SAConnection::setAPI method with SAPI object initialized withSA_Informix_Client
constant before
For more details see Getting Started - Connect to Database, SAConnection object, SAConnection::Connect.
Transaction isolation levels
SQL-92 defines four isolation levels, all of which are supported by SQLAPI++:
- Read uncommitted (the lowest level where transactions are isolated just enough to ensure that physically corrupt data is not read)
- Read committed
- Repeatable read
- Serializable (the highest level, where transactions are completely isolated from one another)
SQLAPI++ maps different isolation levels on Informix in the following way:
SA_ReadUncommitted | → | SQL_TXN_READ_UNCOMMITTED |
SA_ReadCommitted | → | SQL_TXN_READ_COMMITTED |
SA_RepeatableRead | → | SQL_TXN_REPEATABLE_READ |
SA_Serializable | → | SQL_TXN_SERIALIZABLE |
In addition to the SQL-92 levels, if you specify 'snapshot' isolation level, it will be mapped as: SA_Snapshot
→ SQL_TXN_SERIALIZABLE
.
For more details see SAConnection::setIsolationLevel.
Working with Long or Lob (CLob, BLob) data
When fetching data SQLAPI++ detects data types of the columns in the result set and maps those types to internal library types. The mapping determines which native APIs the library will use for fetching LOB data.
The table below shows how SQLAPI++ maps Informix server data types
to Long/Lob library types
:
BYTE, BLOB | → | SA_dtLongBinary |
TEXT, CLOB | → | SA_dtLongChar |
When binding input data from your program the reverse mapping is taking place. The SQLAPI++ data type you use for input markers determines what native API program types will be used for sending Long/Lob data to the server.
library types
to Informix API data types
:SA_dtLongBinary | → | SQL_LONGVARBINARY |
SA_dtLongChar | → | SQL_LONGVARCHAR, SQL_WLONGVARCHAR | SQL_UNICODE_LONGVARCHAR |
SA_dtBLob | → | SQL_LONGVARBINARY |
SA_dtCLob | → | SQL_LONGVARCHAR, SQL_WLONGVARCHAR | SQL_UNICODE_LONGVARCHAR |
For additional information see Getting Started - Handle Long/CLob/BLob.
Returning output parameters
In Informix stored procedure can return zero or more values or sets of values through a result set. After calling SACommand::Execute, use SACommand::FetchNext loop to retrieve these values.
For additional information see SACommand::Execute, SAParam object, Getting Started - Get Output Parameters.
Cancelling queries
Using SACommand::Cancel method you can cancel the following types of processing on a statement:
- function running asynchronously on the statement
- function running on the statement on another thread
SQLAPI++ calls SQLCancel
function to cancel a query. To get more details see SQLCancel
function description in native Informix documentation.
For additional information see SACommand::Cancel.
Connection, command, parameter and field options
Server specific options can be applied at the API, connection, command, parameter or field levels.
We recommend you specify each option at the appropriate level, although it is possible to specify them at the parent object level as well. In that case the option affects all the child objects.
API level options must be specified in SAPI object. If an internal SAPI object is used for the DBMS API initialization (implicit DBMS API initialization, see SAConnection::Connect method) the related DBMS specific options are taken from the initial connection object.
Connection level options may be specified in either SAPI object or SAConnection object. If specified in SAPI object an option affects all connections on that API.
Command level options may be specified in SAPI object, SAConnection object or SACommand object. If specified in a parent object an option affects all commands on that SAPI or SAConnection object.
Parameter level options may be specified in SAPI object, SAConnection object, SACommand object or SAParam object. If specified in a parent object an option affects all parameters on that SAPI, SAConnection or SACommand object.
Field related options may be specified in SAPI object, SAConnection object, SACommand object or SAField object. If specified in a parent object an option affects all fields on that SAPI , SAConnection or SACommand object.
Specific options applicable to Informix:
INFCLI.LIBS
- Windows -
"ICLIT09B.DLL;ICLIT09A.DLL"
- Linux -
"libifcli.so:iclit09a.so:iclit09b.so"
"STATIC"
, forces using the linked Informix-CLI API functions when the library compiled with SA_STATIC_INFORMIX
build option.UseIDSISAMERRMSG
SQL_INFX_ATTR_IDSISAMERRMSG
connection attibute so the error message includes also ISAM error code and text."True"
, "1"
"False"
PreFetchRows
"1"
UseDynamicCursorScrollable
SQL_ATTR_CURSOR_TYPE
= SQL_CURSOR_DYNAMIC
and SQL_ATTR_CONCURRENCY
= SQL_CONCUR_LOCK
."True"
, "1"
"False"
SetCursorName
SQLSetCursorName
documentation.ExecDirect
SQLExecDirect
instead of SQLExecute
API function."True"
, "1"
"False"
SQL_ATTR_QUERY_TIMEOUT
For additional information see SAOptions::setOption.
Using native Informix API
You can call client specific API functions which are not directly supported by SQLAPI++ library. SAConnection::NativeAPI method returns a pointer to the set of native API functions available for Informix. To use the database API directly you have to downcast this IsaAPI pointer to the appropriate type and use its implementation-specific members. The following example shows what type cast you have to make and what additional header file you have to include to work with Informix API. Note that using appropriate type casting depends on an API (that generally mean that you have to explicitly check client version before casting, see SAConnection::ClientVersion method).
To use native API you need to add Informix specific #include
and cast the result of SAConnection::NativeAPI to class infAPI
:
#include "infAPI.h"
IsaAPI *pApi = con.NativeAPI();
infAPI *pNativeAPI = (infAPI *)pApi;
To get more information about Informix API functions see Informix documentation.
For additional information see SAConnection::NativeAPI.
Getting native Informix connection related handles
You have to use native API handles when you want to call specific Informix API functions which are not directly supported by the library. API functions usually need to receive one or more active handles as parameters. SAConnection::NativeHandles method returns a pointer to the set of native API connection related handles. To use API handles directly you have to downcast saConnectionHandles pointer to the appropriate type and use its implementation-specific members.
To access native connection handles you need to add Informix specific #include
and cast the result to class infConnectionHandles
:
#include "infAPI.h"
saConnectionHandles *pHandles = con.NativeHandles();
infConnectionHandles *pNativeHandles = (infConnectionHandles*)pHandles;
To get more information about Informix API functions and handles see Informix specific documentation.
For additional information see SAConnection::NativeHandles.
Getting native Informix command related handles
You have to use native API handles when you want to call specific Informix API functions which are not directly supported by the library. API functions usually need to receive one or more active handles as parameters. SACommand::NativeHandles method returns a pointer to the set of native API command related handles. To use API handles directly you have to downcast saCommandHandles pointer to the appropriate type and use its implementation-specific members.
To access native command handles you need to add Informix specific #include
and cast the result to class infCommandHandles
:
#include "infAPI.h"
saCommandHandles *pHandles = cmd.NativeHandles();
infCommandHandles *pNativeHandles = (infCommandHandles*)pHandles;
To get more information about Informix API functions and handles see Informix specific documentation.
For additional information see SACommand::NativeHandles.
Error handling
When an error occurs when executing a SQL statement SQLAPI++ library throws an exception of type SAException and SAException::ErrPos method returns error position in the SQL statement.
In Informix server SAException::ErrPos method returns -1 because Informix does not support this function.
For additional information see Getting Started - Error Handling, SAException object.